Mead O'Brien: Steam and Hot Water System Experts


Let Mead O’Brien help you create a sustainable Steam Trap Management Process!
  • Trained Survey Technicians 
  • Traps located and identified, tagged with SS tag #, and data logged with up to 27 fields of useful data per trap 
  • Executive summary, Failed trap report with steam & dollar losses, detailed Log sheets, and Recommendations are all provided in a professional report. 
  • Monitoring options presented for critical service applications 
  • Steam flow measurement design 
  • Heat recovery potential 
  • Training options in a live steam lab 
Realize the Savings Now!
  • Reduce steam & condensate losses 
  • Reduce loss of boiler chemicals 
  • Improve heat transfer performance 
  • Prevent coil and heat exchanger damage 
  • Minimize water hammer hazards 


Mead O’Brien and Armstrong, more than 85 years of Steam & Hot Water System Optimization

  • Steam Distribution
  • Process Heat Transfer and Control
  • Condensate Return
  • Heat Recovery Opportunities
  • Process, Ambient & Combustion Air
  • Steam Trap Surveys & Database Creation 
  • Humidification Assessment
  • Application issues
    • - Coil Freezing Issues
    • - Poor Heat Transfer & Steam Control - Water Hammer Issues
    • - High Backpressure
  • Steam & Condensate Measurements, Control & Monitoring

Learning Systems:

  • Armstrong University
  • Over 125 web-based courses 
  • Mead O’Brien Live Steam Lab
  • Content Tailored for Plant Need

Steam Trap Testing Guide for Energy Conservation

steam trap testing schedule
Annual steam trap testing schedule

Below is a steam trap testing guide (courtesy of Armstrong International) to maximize efficiency and conserve energy. This guide discusses:
  • Steam Trap Testing Procedure 
  • Tips On Listening 
  • Inverted Bucket 
  • Float & Thermostatic Trap 
  • Disc Trap 
  • Thermostatic Trap 
  • Sub-Cooling Trap 
  • Traps on Superheated Steam
CAUTION: Valves in steam lines should be opened or closed by authorized personnel only, following the correct procedure for specific system conditions. Always isolate steam trap from pressurized supply and return lines before opening for inspection or repair. Isolate strainer from pressurized system before opening to clean. Failure to follow correct procedures can result in system damage and possible bodily injury.

Steam System Condensate - Save Big by Managing its Proper Return

Recover condensate
Recover/return steam condensate
An often overlooked place to find savings in the operation of a manufacturing plant is the steam condensate return system. Returning condensate to the boiler feedwater system saves energy by returning pre-heated water, thus requiring less energy to maintain the feed water temperature. Furthermore, condensate is pre-treated, eliminating the need for additional expensive treatment.

Steam use in modern plants is everywhere. The condensate derived from its use is an asset that needs to be recycled. Older steam systems may have poor condensate return piping, or none at all. For these situations, creating or extending return lines should be considered. Steam traps in older systems are also suspect. Older traps are not as efficient or reliable as newer designs.

According to Armstrong International’s Senior Utility Systems Engineer Novena Iordanova, steam traps are very important in the condensate return/feedwater cycle. She believes the first purpose of a steam system is to deliver steam to a users defined area of need, and second, to return the resulting condensate back to the boiler. Unfortunately, in many cases the second goal is overlooked.

In older plants, a complete steam system evaluation, and many times an overhaul, is required. Professionals should be called in as plant maintenance staff typically doesn’t have the expertise required. The reasons for steam system degradation are common in the life cycle of plant operation. Over time, plant upgrades, new lines, expansion, and new equipment can have a significant detrimental effect on condensate return systems. The focus usually goes to the main headers and distribution, but condensate return doesn’t receive the same attention. The result can be a steam system that is no longer efficient - meaning high back pressures, water hammer, broken or freezing pipes, and leaks. At that point, the plant needs professional help for a complete system review.

steam trap
Steam trap
(courtesy of Armstrong)
The most important player in condensate recovery is the steam trap. Steam traps play the critical role of separating steam and condensate at the moment its formed. Traps discharge the condensate downstream to the boiler for reuse. Proper sizing, installation, and maintenance from the start will save huge amounts of money in terms of energy savings and maintenance time.

Frequent and regular inspections of steam traps are essential, but in reality they are many times postponed or rescheduled. Steam trap inspection is tough work. Traps are usually located in hard to see, hot, and tight areas. Over time, the difficulty (combined with the perceived low priority) degenerates to spotty inspection routines, higher trap fail rates and higher steam costs.

The good news is that steam trap monitoring systems now exist that can monitor the performance of steam traps and alert maintenance when things start to deteriorate. Steam trap monitoring systems report conditions that point to filature, and also alarm when things break down. Accordingly, maintenance is in a position to take preventive action, or make swift repairs. Any plant with a considerable number of stream traps should strongly consider deploying a steam trap monitoring system.

Steam trap monitoring systems monitor the thermal and acoustic characteristic of the trap and report any significant changes. Today many monitoring systems are wireless, and many operate on common plant communication systems such as WirelessHART, a communication protocol gaining worldwide acceptance.

Its important to mention here though, the on the most common mistake plant personnel make when it comes to their system is also one of  the most obvious - insulation. The use of high quality, well maintained insulation, installed to allow access to steam components is critical. The energy savings alone from well insulated pipes and traps is argument enough for making the initial time and dollar investment for proper insulating.

If you’re a plant manager and are looking for significant measurable and meaningful ways to lower energy costs, you must consider a well planned and well executed steam trap management program.

Happy New Year from the Mead O'Brien Team

Everyone at Mead O'Brien would like to wish all of our customers, vendors, suppliers, families and friends a very happy, healthy and prosperous 2016!

We look forward to serving our customers and working alongside you for our mutual success and growth.

Cheers!
The Mead O'Brien Team

The Rotary Globe Control Valve

Neles Rotary Control Valve
Neles Rotary Control Valve
Neles, a division of Metso, offers their "RotaryGlobe" control valve designed to control a wide range of process liquids, gases and vapors. Its provides reliable and rugged construction and is available with a variety of different trim choices.  An excellent candidate for general, difficult and even severe service control valve applications for many industries including chemical, petrochemical, water treatment, pulp and paper, and power generation. The Neles RotaryGlobe valve provides excellent control accuracy with the inherent benefits of a rotary valve. The optimized design results in reliability and control stability and also reduces lifetime costs and maintenance needs.

See the video below for a "look inside".

Valves Designed for Severe Service. Not Just Heavy Duty

severe service control valve
High performance butterfly
valve (Jamesbury)
From time to time, industrial process control applications involve very stringent and challenging performance requirements for the valves, process piping, and instruments that are part of the control loop. Control valves are a significant example where the impact of extreme fluid conditions require careful design and selection consideration to assure proper performance and safety levels are maintained in a predictable way.

Severe service is a term that describes valves used in application at the extremes of pressure, temperature, cycling, and material compatibility. While there are plenty of published and accepted standards for industrial valves, one does not exist to precisely define a severe service valve.


So, what then defines the selection of severe service valves, as opposed to general purpose valves?

There are a number of basic selection criteria that might point you in that direction, but in general they are:
  • Very extreme media or environmental temperature
  • High pressure drop operation that may cause cavitation
  • Rapid and extreme changes to inlet pressure
  • Certain types or amounts of solids contained in the fluid
  • Highly corrosive, or erosive process media.
Certainly, any of these criteria might be found in an application serviceable by a general purpose valve, but their presence should be an indicator that a more involved assessment of the fluid conditions and commensurate valve requirements is needed. The key element for a specifier is to recognize when conditions are apparent that might exceed the capabilities of a general purpose valve, leading to premature failure in control performance or catastrophic failure that produces an unsafe condition. Once the possibility of a severe service condition is identified, a careful analysis of the possible operating conditions will reveal the performance requirements for the valve.

When in doubt, its critical to discuss your special requirements with an experienced product application specialist. They have access to technical resources that can help with selecting the right valve components to meet your severe service applications.

For more information contact:

Mead O'Brien
(800) 892-2769

Closed Loop Control System Basics

closed loop control
Closed loop diagram
The video below explains the concept of a closed loop control system, using a steam heat exchanger and food processing application as an example.

A closed loop control system uses a sensor that feeds current system information back to a controller. That information is then compared to a reference point or desired state. Finally, a a corrective signal is sent to a control element that attempts to make the system achieve its desired state.

A very basic example of a temperature control loop includes a tank filled with product (the process variable), a thermocouple (the sensor), a thermostat (the controller), and a steam control valve feeding a tubing bundle (the final control element).

The video outlines all the major parts of the system, including the measured variable, the set point, the controlled variable, controller, error and disturbance.